20 set igmp lookup-interval-unknown, 21 set igmp lookup-resp-time-unknown, 20set igmp lookup-interval-unknown – Pilz PSSnet SHL 8T MRP User Manual
Page 138: 21set igmp lookup-resp-time-unknown

138
4.6 Device Configuration Commands
PSSnet SHL - Command Line Interface
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
4.6.20 set igmp lookup-interval-unknown
This command configures the IGMP Snooping lookup response time for
unknown multicast frames (unit: seconds, min.: 2, max.: 3599, default: 125).
Format
set igmp lookup-interval-unknown <2-3599>
Mode
Global Config
<2-3599>
Enter the IGMP Snooping lookup response time for unknown multi-
cast frames (unit: seconds, min.: 2, max.: 3599, default: 125).
4.6.21 set igmp lookup-resp-time-unknown
This command configures the IGMP Snooping lookup interval for unknown
multicast frames (unit: seconds, min.: 1, max.: 3598, default: 10).
Format
set igmp lookup-resp-time-unknown <1-3598>
Mode
Global Config
<2-3598>
Enter the IGMP Snooping lookup interval for unknown multicast
frames (unit: seconds, min.: 1, max.: 3598, default: 10).