24 temperature, 24temperature 213 – Pilz PSSnet SHL 8T MRP User Manual
Page 213

PSSnet SHL - Command Line Interface
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
4.8 System Utilities
213
trap
Configures the sending of traps concerning the signal contact.
– enable enables sending traps,
– disable disables sending traps.
4.8.24 temperature
This command configures the lower and upper temperature limit for the
device. If these limits are exceeded, a trap is sent. The unit for the
temperature limit is °C (Celsius), the minimum value is -99, the maximum val-
ue is 99. The default for the lower limit is 0, for the upper limit, it is 70.
Note: to give the temperature in Fahrenheit, use the suffix f.
Format
temperature {lower-limit|upper-limit}
Mode
Global Config
lower-limit
Configure the lower temperature limit.
lower-upper
Configure the upper temperature limit.