4.8 System Utilities
PSSnet SHL - Command Line Interface
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
4.8.23 signal-contact
This command configures the signal contacts.
Format
signal-contact {1|2|all}
{mode {auto|device-status|manual}
|monitor {aca-removal|all|
connection-error|hiper-ring|module-removal
|power-supply-1| power-supply-2
|power-supply-3-1|power-supply-3-2
|power-supply-4-1|power-supply-4-2
|ring-coupling|temperature} {disable|enable}
|state {closed|open}
|trap {disable|enable} }
Mode
Global Config
Contact No.
Selection of the signal contact:
– 1 signal contact 1,
– 2 signal contact 2,
– all signal contact 1 and signal contact 2.
mode
Selection of the operational mode:
– auto function monitoring,
– device-status the device-status determines the signal contact´s
status.
– manual manually setting the signal contact.
monitor
Enables or disables the monitoring of the selected event or all events.
– enable monitoring,
– disable no monitoring.
state
Set the manual setting of the signal contact:
– closed ,
– open.
Only takes immediate effect in manual mode.