beautypg.com

3 ring-coupling config – Pilz PSSnet SHL 8T MRP User Manual

Page 303

background image

CLI Commands: Switching

PSSnet SHL - Command Line Interface

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany

5.5 Redundant Coupling

303

5.5.3 ring-coupling config

This command sets the Ring Coupling configuration.

Possible values are:

D

single Configure the Ring Coupling's basic setting to single (both cou-

pling ports are local to the switch, switch performs master and slave func-
tions).

D

dual-master-inband Configure the Ring Coupling's basic setting to

dual-master-inband (2nd coupling port is on a remote switch, local switch
is master, communication over network).

D

dual-master-outband Configure the Ring Coupling's basic setting to

dual-master-outband (2nd coupling port is on a remote switch, local
switch is master, communication over dedicated control port).

D

dual-slave-inband Configure the Ring Coupling's basic setting to

dual-slave-inband (2nd coupling port is on a remote switch, local switch is
slave, communication over network).

D

dual-slave-outband Configure the Ring Coupling's basic setting to

dual-slave-outband (2nd coupling port is on a remote switch, local switch
is slave, communication over dedicated control port).

D

dmi Abbreviation for dual-master-inband.

D

dmo Abbreviation for dual-master-outband.

D

dsi Abbreviation for dual-slave-inband.

D

dso Abbreviation for dual-slave-outband.

Default

none

Format

ring-coupling conf <{single|dual-master-
inband|dual-master-outband|dual-slave-inband|dual-
slave-outband|dmi|dmo|dsi|dso}>

Mode

Global Config

This manual is related to the following products: