beautypg.com

Comtrol UP DeviceMaster User Guide User Manual

Page 97

background image

DeviceMaster UP Modbus/TCP User Guide: 2000447 Rev. I

Chapter 4. Diagnostic and Statistics Pages - 97

PLC Interface Diagnostics

PLC Interface Diagnostics (cont.)

Unexpected Event
Errors

Displays the number of unexpected event errors. Unexpected event errors
occur when the DeviceMaster UP receives an unexpected message from the
PLC such as an unexpected response or unknown message.

Unsupported CIP
Request Instance Errors

Displays the number of unsupported CIP request instance errors. These
errors occur when a message with an invalid instance is sent to the
DeviceMaster UP.

Unsupported CIP
Request Service Errors

Displays the number of unsupported CIP request instance errors. These
errors occur when a message with an invalid service is sent to the
DeviceMaster UP.

Unsupported CIP
Request Class Errors

Displays the number of unsupported CIP request instance errors. These
errors occur when a message with an invalid class is sent to the
DeviceMaster UP.

Unsupported CIP
Request Attribute
Errors

Displays the number of unsupported CIP request instance errors. These
errors occur when a message with an invalid attribute is sent to the
DeviceMaster UP.

Improper Configuration
Errors

Displays the number of improper configuration errors. These errors occur
when the DeviceMaster UP receives a message that cannot be performed
due to an invalid configuration.

Invalid Message Data
Errors

Displays the number of invalid message data errors. These errors occur
when the DeviceMaster UP receives a message that cannot be performed
due to invalid data.

System Resource Errors

Displays the number of system resource errors. These errors indicate a
system error on the DeviceMaster UP such as an inoperable serial port or a
full transmit queue. These errors typically occur when the PLC(s) are
sending data to the DeviceMaster UP faster than the DeviceMaster UP can
process it.

Oversized Received
Data Packet Errors

Displays the number of received Ethernet data packets that were larger
than the configured maximum receive data packet.

Writes to Offline
Ethernet Device on
Socket N

Displays the number of write attempts by a PLC to the Ethernet device
when the device was offline.