Messages, Devicemaster up file addressing – Comtrol UP DeviceMaster User Guide User Manual
Page 58

58 - Chapter 2. Programming Interface
DeviceMaster UP Modbus/TCP User Guide: 2000447 Rev. I
Messages
2.4.2. Messages
The PLC-5 and SLC 5/05 PLCs support the following PCCC messages:
2.4.2.1. DeviceMaster UP File Addressing
The following tables display the DeviceMaster UP file addressing for the PLC-5/SLC messages.
Note: There are no statistics available for the Ethernet socket ports.
Message Type
PCCC Message ID
Maximum Message Size
Maximum Serial Packet Size
SLC Typed Read
162
CLX: 242 SINTs (121 INTs)
SLC: 206 SINTs (103 INTs)
PLC-5: 240 SINTs (120 INTs)
CLX: 238 SINTs (119 INTs)
SLC: 202 SINTs (101 INTs)
PLC-5: 236 SINTs (118 INTs)
SLC Typed Write
170
CLX: 220 SINTs (110 INTs)
SLC: 206 SINTs 103 INTs)
PLC-5: 238 SINTs (119 INTs)
216 SINTs (108 INTs)
SLC: 202 SINTs (101 INTs)
PLC-5: 234 SINTs (117 INTs)
PLC-5 Typed Read
104
CLX: 234 SINTs (117 INTs)
SLC: 252 SINTs (126 INTs)
PLC-5: 238 SINTs (119 INTs)
230 SINTS (115 INTs)
SLC: 248 SINTs (124 INTs)
PLC-5: 234 SINTs (117 INTs)
PLC-5 Typed Write 103
CLX: 226 SINTs (113 INTs)
SLC: 226 SINTs (113 INTs)
PLC-5: 224 SINTs (112 INTs)
CLX: 222 SINTs (111 INTs)
SLC: 222 SINTs (111 INTs)
PLC-5: 220 SINTs (110 INTs)
Serial
Port
Number
Receive
Data
Receive Data
Produced
Sequence Number
Receive Data
Consumed
Sequence Number
Transmit
Data
Transmit Data
Sequence
Number
Statistics
1
N10:0
N10:128
N10:129
N11:0
N11:128
N12:0
2
N20:0
N20:128
N20:129
N21:0
N21:128
N22:0
3
N30:0
N30:128
N30:129
N31:0
N31:128
N32:0
4
N40:0
N40:128
N40:129
N41:0
N41:128
N42:0
Socket
Port
Number
Receive
Data
Receive Data
Produced
Sequence Number
Receive Data
Consumed
Sequence Number
Transmit
Data
Transmit data
Sequence
Number
1
N50:0
N50:128
N50:129
N51:0
N51:128
2
N60:0
N60:128
N60:129
N61:0
N61:128
3
N70:0
N70:128
N70:129
N71:0
N71:128
4
N80:0
N80:128
N80:129
N81:0
N81:128