What is rslogix 500, Requirements, What is rslogix 500? 5.4.2. requirements – Comtrol UP DeviceMaster User Guide User Manual
Page 116: Slc or, Micrologix plc programming example instructions, 116 describ

116 -
Chapter 5. Programming the PLC
DeviceMaster UP EtherNet/IP User Guide: 2000424 Rev. L
SLC or MicroLogix PLC Programming Example Instructions
5.4. SLC or MicroLogix PLC Programming Example Instructions
This topic describes how to use RSLogix 500 to configure and run the DeviceMaster UP in an SLC or
MicroLogix PLC environment.
You can configure the RSLogix 500 PLC program examples to your site’s requirements. These programs are
included in the self-installing file (.MSI) and are copied to the Comtrol/EtherNetIP directory on your computer
when you open the .MSI file and follow the prompts. The self-installing file includes the following RSLogix
500 PLC program examples:
•
5.4.3.1. lpbkExampleSlcMsgPollRS500 - SLC PLC
•
5.4.3.2. lpbkExamplePlc5MsgPollRS500 - SLC PLC
These program examples are intended to aid the PLC programmer. These program examples were developed
with version 6.30.00 (CPR 6) of RSLogix 500 and a C series SLC 5/05 with FRN 9 firmware.
Note: The PLC program examples are designed to interface with a DeviceMaster UP 1-port or on Port 1 of a 2-
port or 4-port. Additional programming is required to use all ports on a 2-port or 4-port.
Disclaimer: Comtrol supplies example PLC programs for demonstration purposes only.
They are intended for the sole purpose of an example loop-back demonstration in a
controlled lab environment. They are not intended for use in a production environment
and may not function correctly on all PLCs. Comtrol does not warrant these example
programs or any part thereof. The user assumes all liability for any modification to and
use of a modified example program.
5.4.1. What is RSLogix 500?
RSLogix 500 is a Windows ladder logic programming package for the SLC 500 and MicroLogix PLCs.
Note: See the RSLogix 500 Help for more information on this product.
5.4.2. Requirements
•
The DeviceMaster UP must be installed and configured as described in the
Installation and Configuration Guide
•
The DeviceMaster UP must be installed on the same Ethernet network segment as the PLC.
•
RSLogix 500 must be installed on your computer. Note that the instructions in this guide require that you
have some familiarity with this programming application.
•
A loopback plug is required for the first port on the DeviceMaster UP when running an example PLC
program. If necessary, see the
DeviceMaster UP Hardware Installation and Configuration Guide
for
information on loopback plugs.
•
The PLC program examples (.SLC, .SY5 and .SY6 files) are optional. You can copy the PLC program
examples from the CD or download the latest program examples from the Internet. See
on Page 10, for the location of the PLC program examples.
Caution