Comtrol UP DeviceMaster User Guide User Manual
Page 25

DeviceMaster UP Modbus/TCP User Guide: 2000447 Rev. I
Chapter 2. Programming Interface - 25
Instance Attribute Definitions
Attribute 27
Application Connect
Mode
This setting controls if and how the DeviceMaster UP attempts to connect to the
application at the application connection IP address and application connection socket
port.
•
0 = Never - The DeviceMaster UP does not attempt to connect to the application.
•
1 = Connect Always - The DeviceMaster UP attempts connecting to the
application socket port until a connection is made.
•
2 = Connect On Data - The DeviceMaster UP does not attempt to connect to the
application socket port until there is data to send to the application. Once data is
received from the serial device, the DeviceMaster UP attempts connecting to the
application until a connection is made.
Attribute 28
Application
Disconnect Mode
This setting controls if and how the DeviceMaster UP disconnects from an application.
•
0 = Never - The DeviceMaster UP does not disconnect from the application socket
port.
•
1 = Disconnect On Idle - The DeviceMaster UP disconnects when there has been
no transmit or received data between the serial device and application socket port
for a specified Idle period (Attribute 32: Application Connection IP Address).
Attribute 29
Application Listen
Socket Port
This is the socket port number on the DeviceMaster UP the application connects to if
Application Listen Enable is enabled.
Attribute 30
Application
Connection Socket
Port
This is the application socket port number the DeviceMaster UP connects to if the
Application Connect Mode is set to either Connect Always or Connect On Data.
Attribute 31
Application
Connection IP
Address
This is the application IP address in hexadecimal format that the DeviceMaster UP
connects to if the Application Connect Mode is set to either Connect Always or Connect
On Data. For example, an IP address of 10.1.2.100 is 0A010264 in hexadecimal.
Attribute 32
Application Idle
Timeout
The idle timeout period in milliseconds that is used if the Application Disconnect Mode
is set to Disconnect On Idle.
Attribute 33
To PLC Filter/Data
Extraction Mode
The filter/data extraction mode to be employed on data to be sent to the PLC.
•
0 = Off
•
1 = String (128 char max) - Raw/ASCII data is filtered up to 128 characters (or
bytes) in length.
•
2 = RFID (EPCglobal formats) - RFID data in any of the EPCglobal formats is
filtered, the associated parameters is extracted, and the extracted data and RFID
tag is sent to the PLC in a specified format.
•
3 = Barcode (UPC/EAN formats) - Barcode data in specified UPC/EAN formats is
filtered, the associated parameters is extracted, and the extracted data and
barcode is sent to the PLC in a specified format. See the
in Attribute 41 on Page 28.
See the
DeviceMaster UP Filtering and Data Extraction Reference Guide
further details.
Attribute
Description