beautypg.com

Comtrol UP DeviceMaster User Guide User Manual

Page 19

background image

DeviceMaster UP Modbus/TCP User Guide: 2000447 Rev. I

Chapter 2. Programming Interface - 19

Instance Attributes

41

Barcode Formats

(Barcode Filtering Only)

UINT

Standard 12-14 Digit Format

(Mask = 000F Hex)

00 Hex=NONE

01 Hex=Five Company/Five Product

Digits

02 Hex=Six Company/Four Product

Digits

03 Hex=Seven Company/Three Product

Digits

04 Hex=Eight Company/Two Product

Digits

05 Hex=Nine Company/One Product

Digits

Eight Digit Format

(Mask = 00F0 Hex)

00 Hex=NONE

10 Hex=EAN-8; Two Company/Five

Product Digits

20 Hex=EAN-8; Three Company/Four

Product Digits

30 Hex=UPC-E

Set/Get

42

(Default=0)

Application Transmit STX Append Value
Structure of:

Length

Value1 (Only valid if Length

not zero)

Value2 (Only valid if

Length=2)

USINT

USINT

USINT

0,1,2 (0=No STX) (Default=0)

0 to 255

0 to 255

Set/Get

43

(Default=0)

Application Transmit ETX Append Value
Structure of:

Length

Value1 (Only valid if Length

not zero)

Value2 (Only valid if

Length=2)

USINT

USINT

USINT

0,1,2 (0=No ETX) (Default=0)

0 to 255

0 to 255

Set/Get

44

Reserved

USINT[2] 0

Get

Attribute ID

Name

Data

Type

Data Value(s)

Access

Rule