Comtrol UP DeviceMaster User Guide User Manual
Page 19

DeviceMaster UP Modbus/TCP User Guide: 2000447 Rev. I
Chapter 2. Programming Interface - 19
Instance Attributes
41
Barcode Formats
(Barcode Filtering Only)
UINT
Standard 12-14 Digit Format
(Mask = 000F Hex)
00 Hex=NONE
01 Hex=Five Company/Five Product
Digits
02 Hex=Six Company/Four Product
Digits
03 Hex=Seven Company/Three Product
Digits
04 Hex=Eight Company/Two Product
Digits
05 Hex=Nine Company/One Product
Digits
Eight Digit Format
(Mask = 00F0 Hex)
00 Hex=NONE
10 Hex=EAN-8; Two Company/Five
Product Digits
20 Hex=EAN-8; Three Company/Four
Product Digits
30 Hex=UPC-E
Set/Get
42
(Default=0)
Application Transmit STX Append Value
Structure of:
Length
Value1 (Only valid if Length
not zero)
Value2 (Only valid if
Length=2)
USINT
USINT
USINT
0,1,2 (0=No STX) (Default=0)
0 to 255
0 to 255
Set/Get
43
(Default=0)
Application Transmit ETX Append Value
Structure of:
Length
Value1 (Only valid if Length
not zero)
Value2 (Only valid if
Length=2)
USINT
USINT
USINT
0,1,2 (0=No ETX) (Default=0)
0 to 255
0 to 255
Set/Get
44
Reserved
USINT[2] 0
Get
Attribute ID
Name
Data
Type
Data Value(s)
Access
Rule