Chapter 5. Programming the PLC

DeviceMaster UP EtherNet/IP User Guide: 2000424 Rev. L

Configure and Run the Example RSLogix 5 Program

10. Double-click Channel Configuration and click the Channel 3A tab.

Note: The port number for the Ethernet channel may be

different on your PLC-5.

11. In the Ethernet Configuration panel, make the following

changes:

a.

Set Channel Type to Ethernet.

b.

Type 60 in the Diagnostic File box. You can use the
diagnostic file to help solve any network-related problems.

c.

Type the IP address for your PLC-5 in the IP address box.

d.

Type the subnet mask for your PLC-5 in the Subnet Mask
box.

e.

Type the gateway address for your PLCI-5 in the Gateway
Address
box.

f.

If applicable to your network, type the addresses for the
Primary Name Server and Secondary Name Server.

12. Click OK to apply your changes and close the Channel

Configuration dialog.

13. In the ladder logic, double-click Setup Screen in an MSG

instruction.

14. Select the MultiHop tab and type the IP address for the

DeviceMaster UP in the To Address box.

15. Close the MSG dialog.

16. Repeat steps 13 through 15 for each MSG instruction in the

ladder logic.

17. Download the PLC program to your PLC and run the program.