beautypg.com

Display ethernet device logs – Comtrol UP DeviceMaster User Guide User Manual

Page 95

background image

DeviceMaster UP Modbus/TCP User Guide: 2000447 Rev. I

Chapter 4. Diagnostic and Statistics Pages - 95

Display Ethernet Device Logs

4.3. Display Ethernet Device Logs

The Ethernet Device Interface Logs page is accessed using the Display Ethernet Device Logs option, which
provides a log of received and transmitted Ethernet device messages. Up to 128 bytes per message and up to
128 messages are logged. It is intended to help with debugging Ethernet connectivity problems, determining
the proper start and end of transmission bytes, and diagnosing device problems.

The format is as follows:

Pkt(n)

: ddd:hh:mm:ss.mmm Rx/Tx:

Where:

ddd – days since last system restart

hh – hours since last system restart

mm – minutes since last system restart

SS – seconds since last system restart

mmm – milliseconds since last system restart

- Data packet received.

ASCII characters displayed as characters

Non-ASCII displayed in hex (xxh) format