Chapter 6. Troubleshooting and Technical Support

DeviceMaster UP Modbus/TCP User Guide: 2000447 Rev. I

General Troubleshooting

6.2. General Troubleshooting

This table illustrates some general troubleshooting tips.

Note: Make sure that you have reviewed the

6.1. Troubleshooting Checklist

on Page 165.

6.3. Technical Support

It contains troubleshooting procedures that you should perform before contacting Technical Support since
they will request that you perform, some or all of the procedures before they will be able to help you diagnose
your problem. If you need technical support, use one of the following methods.

General Condition

Explanation/Action

PWR or Status LED flashing

Indicates that boot program has not downloaded to the unit.

1.

Reboot the system.

2.

Make sure that you have downloaded the most current
firmware for your protocol:

http://www.comtrol.com/support/download.asp

.

Note: If the PWR or Status LED is still flashing, contact

Technical Support.

PWR or Status LED not lit

Indicates that power has not been applied or there is a hardware
failure. Contact Technical Support.

Cannot ping the device through
Ethernet hub

Isolate the DeviceMaster UP from the network. Connect the
device directly to the NIC in the host system (see Page 165).

Cannot ping or connect to the
DeviceMaster UP

The default IP address is often not accessible due to the subnet
masking from another network unless 192.168 is used in the
network.

In most cases, it is necessary to program in an address that
conforms to your network.

DeviceMaster UP continuously
reboots when connected to some
Ethernet switches or routers

Invalid IP information may also cause the switch or router to
check for a gateway address. Lack of a gateway address is a
common cause.