Installing interface modules, Installing wan port interface modules (wpims) – Cabletron Systems HSIM-W6 User Manual
Page 64
Chapter 5: Installation
50
HSIM-W6 User’s Guide
•
Maintain a temperature of between 5
°
C (41
°
F) and 40
°
C (104
°
F) at the installation site with
fluctuations of less than 10
°
C (50
°
F) per hour.
•
Maintain a two-inch clearance for each side and the back of the device for adequate ventilation.
Installing Interface Modules
Depending on your specific application, install Cableton Systems WAN Port Interface Modules
(WPIMs) and the CSX-COMP/ENCR into the HSIM-W6 before proceeding with the installation
of your HSIM-W6. Refer to the
Installing WAN Port Interface Modules (WPIMs)
and
sections within this chapter for installation instructions.
Installing WAN Port Interface Modules (WPIMs)
To install a WPIM into the HSIM-W6, refer to
following steps:
1.
Attach the antistatic wrist strap to your wrist (refer to the instructions on the antistatic wrist
strap package).
2.
Remove and save the three screws from the WPIM standoffs (see Figure 2). Remove the WPIM
coverplate.
!
CAUTION
The WPIMs and CSX-COMP/ENCR for the HSIM-W6 are sensitive to static
discharges. Use a grounding strap and observe all static precautions during
installation. Failure to do so could result in damage to the WPIMs, CSXCOMP/ENCR,
and the HSIM-W6.
NOTE
The HSIM-W6 must have at least one EPIM and one WPIM installed before you can
begin configuring the device.
NOTE
Both WAN ports can be populated. However, if only a single WPIM is used to
communicate and configure your HSIM-W6, WIDE AREA 1 port must have a WPIM
installed.