beautypg.com

Gathering the tools and equipment – ADS Environmental Services FlowShark QR 775003 A2 User Manual

Page 85

background image

3-28

ADS FlowShark IS Manual

1

Additional models of the FlowShark IS monitor are also available: 5000-IS1-US

(without internal battery), 5000-IS1 (for EU without internal battery), and 5000-IS1-

01 (for EU, with internal battery).

2

Extension cables can be ordered in specific lengths up to 300 feet. Note the desired

length (in feet) in the xxx portion of the part number. For example, if the application

requires a 50-foot extension cable for an IS ultrasonic sensor, the part number would

be 106137A–050.

3

IS pressure depth sensors are also available in 0–15 psi (p/n 3754–0002–40) and 0–

30 psi (p/n 3754–0003–40).

Gathering the Tools and Equipment

Gather the following tools for the installation:

Battery-powered hammer drill with assorted bits, including the

following at a minimum:

3/8-inch x 4-inch (minimum length) masonry bit

¼-inch masonry bit (F35-0018)

5/16-inch carbide-tipped drill bit (include smaller bits)

4-pound hammer

Rubber mallet

24-inch carpenter’s level

Wrenches

Screwdrivers (flathead and Phillips head of assorted sizes)

3/8-inch x 16-inch threads tap

Diagonal wire cutters

Folding carpenter’s rule with a brass slide

Mastic tape (ADS p/n 507193) or rubber coaxial stretch tape