Gathering the tools and equipment – ADS Environmental Services FlowShark QR 775003 A2 User Manual
Page 85

3-28
ADS FlowShark IS Manual
1
Additional models of the FlowShark IS monitor are also available: 5000-IS1-US
(without internal battery), 5000-IS1 (for EU without internal battery), and 5000-IS1-
01 (for EU, with internal battery).
2
Extension cables can be ordered in specific lengths up to 300 feet. Note the desired
length (in feet) in the xxx portion of the part number. For example, if the application
requires a 50-foot extension cable for an IS ultrasonic sensor, the part number would
be 106137A–050.
3
IS pressure depth sensors are also available in 0–15 psi (p/n 3754–0002–40) and 0–
30 psi (p/n 3754–0003–40).
Gathering the Tools and Equipment
Gather the following tools for the installation:
Battery-powered hammer drill with assorted bits, including the
following at a minimum:
3/8-inch x 4-inch (minimum length) masonry bit
¼-inch masonry bit (F35-0018)
5/16-inch carbide-tipped drill bit (include smaller bits)
4-pound hammer
Rubber mallet
24-inch carpenter’s level
Wrenches
Screwdrivers (flathead and Phillips head of assorted sizes)
3/8-inch x 16-inch threads tap
Diagonal wire cutters
Folding carpenter’s rule with a brass slide
Mastic tape (ADS p/n 507193) or rubber coaxial stretch tape