ADS Environmental Services FlowShark QR 775003 A2 User Manual
Page 218
A-2
ADS FlowShark IS Manual
Internal Power
One ADS 9-volt or 12-volt IS alkaline battery pack
powering the monitor and one ADS non-IS 12-volt
alkaline battery pack powering the External
Modem Unit.
Battery Life
Monitor (9-volt battery pack): 9-12 months at a
15-minute sample rate with weekly
communications.
Monitor (12-volt battery pack): 11-15 months at a
15-minute sample rate with weekly
communications.
EMU: 2-3 months at a 15-minute sample rate
with weekly communications.
Note: Actual battery life will vary depending on
operating temperature and frequency of
communications.
External Power
Option
Requires an external, low-noise DC power source
providing a minimum of 12 volts at 1 amp
Connectors
U.S. MIL-C-26482 series 1, for environmental
sealing, with gold-plated contacts and interfacial
seals
Inputs and
Outputs
•
IS Ultrasonic depth sensor input
•
IS Doppler velocity sensor input
•
IS Pressure depth sensor input
•
IS Communication/External Power input
•
Air pressure valve (for testing purposes only)
Approvals
Hazardous Area – approved for use in Class I,
Div. 1, Group C&D areas, in US via QPS/UL Cert,
and in Zone 0 IIG areas in the EU via SIRA/ATEX