ADS Environmental Services FlowShark QR 775003 A2 User Manual
Page 154

Configuration and Activation 6-25
Monitor Diagnostics dialog
2. Click on the Connect button to establish communication with
the monitor.
Profile initiates communication with the monitor and
establishes a connection.
3. Select Activate from the Functions drop-down list, and then
click on the Perform button.
Profile downloads the configuration and installation
information, activates the monitor, and begins logging data
based on the selected configuration.
4. Click on the Disconnect button once activation is successful
(designated in the Results section) and complete.
The local computer disconnects from the monitor.
5. Click on the Close button to exit the Monitor Diagnostics
dialog.