beautypg.com

Editing the ultrasonic device – ADS Environmental Services FlowShark QR 775003 A2 User Manual

Page 143

background image

6-14

ADS FlowShark IS Manual

Editing the Ultrasonic Device

Edit the ultrasonic device in the following way, and then click on

the OK button when complete:

Edit Ultrasonic Device Properties dialog

Use Defaults

Select this checkbox to apply the default

parameters to the ultrasonic device. Deselecting this option

enables the parameter fields for editing.

Physical Offset

Enter the physical distance between the face

of the ultrasonic depth sensor and the top (crown) of the pipe.

Scrubbing Window

Enter the allowable difference between

individual ultrasonic pair readings and the average reading of

all the pairs. If any single pair exceeds the difference, that pair

will be flagged and removed from the calculation. The

remaining pairs will be averaged to calculate the depth

readings.

Temperature Offset

This field should not require

modification for the FlowShark IS monitor. No additional
temperature compensation is necessary.

Blanking (auto)

Select this checkbox to ensure the monitor

disregards depths occurring within a distance from the face of

the ultrasonic depth sensor equivalent to 5 percent of the range