2 rcc return values – Banner PresencePLUS P4 COLOR Series User Manual
Page 324

Comments
Optional
Qualifiers
Required
Qualifiers
Support Actions
Object or
Activity
Identifier
System Object,
Component, or
Activity
Enables frame
number as
None
ENABLE
SET
FRAMETAG
Frame Number
Tag
command
acceptance
indicator
Disables frame
number as
None
DISABLE
SET
FRAMETAG
Frame Number
Tag
command
acceptance
indicator
Retrieve the status
of the frame tag
indicator
None
None
GET
FRAMETAG
Frame Number
Tag
8.7.2 RCC Return Values
RCC return values are numeric, and are listed below:
• 0 - command accepted. This return code is generated when a valid SET, GET, and EXEC command has been completely
handled by the sensor. It may be followed by a command-specific return value or a completion code.
If the frame tag is enabled, the current frame number will be returned instead of 0 as command acceptance indicator.
• -100 - Invalid command entered by the user.
• Trigger and Product Change error codes:
• -201 - Product change command attempted in the middle of the inspection
• -202 – Trigger command attempted in the middle of product change
• -203 – Trigger command is attempted when the inspection is not executing (sensor is idle)
• -204 – Specified inspection slot is out of range
• -205 – Trigger command attempted in the middle of the inspection
• -206 – Product change command attempted in the middle of a product change
• -207 – Product change command attempted while the sensor is in the Teach mode
• -208 – Product change attempted when the GUI is connected, and the inspection is not executing
• Comm tool error codes
• -301 – get/set tool command attempted while the inspection is not executing
• -302 – get command issued before inspection is triggered for the first time – tool results unavailable
• -303 – get/set tool command attempted in the middle of the inspection
• -304 – get/set tool command attempted in the middle of the product change
• -305 – Tool specified in get/set command not found in the inspection
• -306 – Requested comm tool is not configured for RCC
• -307 - Tool executed with an error or did not execute
• -308 - Specified tool operand is not a constant, and cannot be modified
• Reset command error codes
• -401 – Reset command attempted in the middle of the inspection
• -402 – Reset command attempted in the middle of the product change
• -500 – RCC commands are not accepted because the sensor is in the Playback mode
• Timeout error codes
Banner Engineering Corp.