Features
•
Strobe control module for Banner strobed LED lights
•
Two independently-adjustable strobe light output circuits designed to strobe LED
lights up to 60 Hz
•
Direct plug-in connection to Banner strobed LED lights via the 9-pin
D-sub connector available on models of strobed lights
•
Removable (plug-in) terminal block for power and trigger signal connections
•
Separate trigger inputs for each output channel; inputs accept 5 to 12V dc trigger
signal
•
Simple switch selection of either high to low or low to high trigger signal
•
One 3 m (10') shielded cable for trigger signal is supplied
•
Output pulse width adjustable using binary DIP switches from 5 to 1,315 microseconds
(separate adjustment for each output channel)
•
Black anodized aluminum housing
Specifications for Model SCM
†
Strobe Control Module
WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or
replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty
period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any
other warranty either expressed or implied.
Environmental Rating
IEC IP20; NEMA 1
Operating Conditions
Temperature: 0° to 40°C (+32° to 104° F)
Maximum relative humidity: 95% at 40°C (non-condensing)
Input Power
24V dc ±5% at 2.0A max.
Power supply model PSC-24(E) is recommended (see Accessories)
Fuse: 5 x 20 mm fast-acting 3A, externally accessible
†
This model is not stocked and is non-returnable.
Outputs
Two independently-adjustable 24V dc ±5% outputs, 9A peak max.
Strobe rate: 60 Hz max.
Pulse duration: Adjustable from 5 to 1,315 microseconds in 10 microsecond increments
Note: Outputs use 9-pin D-sub connectors which allow direct plug-in connection of Banner strobed LED lights
Trigger Inputs
Two inputs - one for each output channel
Each input accepts 5 to 12V dc signal, 10 mA max.
Switch selectable for high to low or low to high trigger signal
Note: Use two-wire shielded cable for trigger signal(s); one 3 m (10') trigger cable is provided with SCM module