Dc common bus configurations – Rockwell Automation 2093-xxxx Kinetix 2000 Multi-axis Servo Drive User Manual User Manual
Page 67
Publication 2093-UM001A-EN-P — January 2007
Connecting the Kinetix 2000 Drive System
67
DC Common Bus
Configurations
When an integrated axis module (IAM) is used in a dc common bus
configuration, the IAM is known as a leader IAM or follower IAM. The IAM
(non-common bus) and leader IAM have identical three-phase input power
connections. The leader IAM is responsible for discharging the dc bus, and for
providing common bus follower drives with dc bus pre-charge, bus regulation,
phase-loss detection, and ground fault detection. Follower IAMs do not have
three-phase input power connections, but have dc bus connections from a
leader IAM.
IAM Terminology and Use
The Kinetix 2000 leader IAM can operate with non-Kinetix 2000 follower
drives, as can the Kinetix 2000 follower IAM operate with non-Kinetix 2000
common bus leader drives. However, non-Kinetix 2000 leader and follower
drives must meet the same functional requirements as the Kinetix 2000 leader
and follower IAMs.
Typical Common Bus Configuration
This IAM
Is Wired
And is
IAM
With three-phase input power.
Not wired in common bus mode.
Leader IAM
With three-phase input power, but has
dc common bus connections to a
follower IAM.
Wired in common bus mode.
Follower IAM
Without three-phase input power, but
has dc common bus connections from
a leader IAM.
Wired in common bus mode and
configured using RSLogix 5000
software.
IMPORTANT
Use Kinetix 2000 drive firmware v1.95.18 and RSLogix 5000 software,
version 16 or later, for common dc bus power configurations.
IMPORTANT
Any non-Kinetix 2000 common bus leader that does not provide
pre-charge is required to add an additional external pre-charge circuit
before connecting to any Kinetix 2000 common bus follower IAM.
DC Common Bus
Bonded
Cabinet
Ground
Bus
Integrated
Axis Module
(2093-AC05-MP
x
)
Axis Modules
(2093-AM
xx
)
Integrated
Axis Module
(2093-AC05-MP
x
)
Axis Modules
(2093-AM
xx
)
170-264V ac
Three-Phase
Input Power
Common Bus
Follower IAM
Common Bus
Leader IAM
Bonded
Cabinet
Ground
Bus
DC Common Bus