beautypg.com

Power specifications, Converter power specifications, To power specifications – Rockwell Automation 2093-xxxx Kinetix 2000 Multi-axis Servo Drive User Manual User Manual

Page 154: 154 f

background image

Publication 2093-UM001A-EN-P — March 2007

154

Specifications and Dimensions

Power Specifications

This section contains power specifications for your IAM or AM components.

Converter Power Specifications

The following tables list power specifications for the converter section that
resides within an integrated axis module.

IAM Converter (three-phase and single-phase) Power Specifications

Attribute

2093-AC05-MPx
Three-phase Input (230V nom)

2093-AC05-MPx
Single-phase Input (230V nom)

Input voltage, ac

170...264V rms

Input frequency, ac

47...63 Hz

Input current, ac main

(1)

Nom (rms)
Max inrush (0-pk)

11.66 A
34.0 A

10.95 A
34.0 A

Input voltage, dc (common bus follower)

240...375V dc

Input current, dc (common bus follower)

9.76 A

6.42 A

Control power ac input voltage

170...264V rms single-phase (230V nom)

Control power ac input current

Nom (@ 230V ac) rms
Max inrush (0-pk)

1.25 A
93.0 A

(2)

Bus output voltage, nom

325V dc

Line loss ride through

20 ms

Continuous output current to bus (A

dc

)

9.67 A

6.42 A

Intermittent output current to bus (A

dc

)

(3)

19.34 A

12.84 A

Bus overvoltage

425V dc

Bus undervoltage

137.5V dc

Internal shunt

Continuous power
Peak power

15 W
3000 W

Internal shunt resistor

50

Ω

Shunt on

405V

Shunt off

375V

Continuous power output to bus

3.0 kW

2.0 kW

Peak power output

6.0 kW

4.0 kW

Efficiency 95%

Converter inductance

N/A

Converter capacitance

540

μF

Converter leakage current (max)

2.0 mA

(1)

All 2093-AC05 integrated axis modules are limited to two contactor cycles per minute (with up to four axis modules), or one contactor cycle per minute (with five to eight
axis modules).

(2)

Maximum inrush duration is less than 1/2 line cycle.

(3)

Intermittent output current duration equals 250 ms.