Noise reduction guidelines for drive accessories – Rockwell Automation 2093-xxxx Kinetix 2000 Multi-axis Servo Drive User Manual User Manual
Page 36

Publication 2093-UM001A-EN-P — March 2007
36
Planning the Kinetix 2000 Drive System Installation
Noise Reduction Guidelines for Drive Accessories
When mounting an ac (EMC) line filter refer to the sections below for
guidelines designed to reduce system failures caused by excessive electrical
noise.
Line Filters, ac
Observe the following guidelines when mounting your ac (EMC) line filter
(refer to the figure on page 33 for an example):
• Mount the line filter on the same panel as the Kinetix 2000 drive and as
close to the power rail as possible.
• Good HF bonding to the panel is critical. For painted panels, refer to
the examples on page 27.
• Segregate input and output wiring as far as possible.
Motor Brake and Thermal Switch
The thermal switch and brake are mounted inside the motor, but how you
connect to the axis module depends on the motor series.
Refer to Wiring the Motor Brake (BC) Connector on page 89 for wiring
guidelines. Refer to Axis Module/Motor Wiring Examples beginning on page
178 for the interconnect diagram of your drive/motor combination.
IMPORTANT
CE test certification applies only to ac line filter and single power rail.
Sharing a line filter with multiple power rails may perform
satisfactorily, but the user takes legal responsibility.