beautypg.com

Control power input, Important – Rockwell Automation 2093-xxxx Kinetix 2000 Multi-axis Servo Drive User Manual User Manual

Page 55

background image

Publication 2093-UM001A-EN-P — March 2007

Kinetix 2000 Connector Data

55

Brake Relay Circuit

(1)

Noise suppression device.

Brake Relay Output Specifications

Control Power Input

The integrated axis module (IAM) requires ac input power for logic circuitry.

Control Power Current Specifications

Control Power Current Requirements

PWR

(BC-1)

BRK-

(BC-3)

BRK+

(BC-2)

COM

(BC-4)

(1)

Kinetix 2000 IAM/AM

Parameter

Description

IAM/AM

Max

On-state current

(1)

(1)

For motors requiring more than the maximum current specified, an external relay must be added. Refer to the
Wiring Example for External Brake Relay Control of Motor Brake on page 182 for a diagram of this circuit.

Current flow when the
relay is closed

2093-AC05-MPx

1.0 A

2093-AMPxx

2093-AMxx

On-state resistance

Contact resistance when the relay is closed

1

Ω

Off-state voltage

Voltage across the contacts when the relay is open

30V

IMPORTANT

For CE certification, the control power input requires an ac line filter
that provides electromagnetic compatibility (EMC). For wiring
examples, refer to Power Wiring Examples beginning on page 169.

IMPORTANT

Source 2093-AC05-MPx (230V) IAM control power from the
three-phase input power (line-to-line). Supplying 230V control power
from any other source requires an isolation transformer. If used, do
not ground either leg of the isolation transformer output.

Refer to Transformer Specifications for Control Power Input on page
159.

Attribute Value

Input voltage

170...264V ac rms,
single-phase or three-phase

Input power frequency

47...63 Hz