Rockwell Automation 2093-xxxx Kinetix 2000 Multi-axis Servo Drive User Manual User Manual
Page 146
Publication 2093-UM001A-EN-P — March 2007
146
Troubleshooting the Kinetix 2000 Drive System
MotFeedbackFault
(Mtr Fdbk AQB)
E20
Motor encoder has encountered an illegal state transition.
DISABLE
N
AuxFeedbackFault
(Aux Feedback Comm)
E21
Communication was not established with an intelligent (Stegmann)
encoder on the Auxiliary feedback port.
STOP
N
MotFeedbackFault
(Motor Feedback Comm)
E30
Communication was not established with an intelligent (Stegmann)
encoder on the Motor feedback port.
STOP
N
GroundShortFault
(Ground Fault)
E34
Excessive ground current in the converter was detected.
SHUTDOWN
N
DriveUndervoltageFault
(Precharge Fault)
E35
The converter pre-charge cycle has failed.
SHUTDOWN
N
DriveOvertempFault
(System Overtemperature)
E36
Converter internal temperature limit exceeded.
SHUTDOWN
N
PowerPhaseLossFault
(Phase Loss Flt)
E37
• One or more phases of the ac input power is missing.
• Axis was enabled when main (three-phase) power was removed.
• Common bus follower axis was enabled when dc bus power was
removed.
SHUTDOWN/ STOP N
SERCOSFault
(SERCOS Ring Flt)
E38
The SERCOS ring is not active after being active and operational.
STOP
N
DriveHardFault
(Self Sense Flt)
E39
Self-sensing commutation fault detected.
DISABLE
N
DriveEnableInputFault
(Drive Enable Flt)
E43
Generated when Enable input switches off when drive is enabled.
STOP
Y
SERCOSFault
(SERCOS Same ADDR)
E50
Duplicate node address detected on SERCOS ring.
STOP
N
DriveHardFault
(Ifbk HW Fault)
E54
Current feedback hardware fault detected.
SHUTDOWN
N
DriveHardFault
(Unknown Axis)
E60
Invalid module type identified by firmware when applying power.
SHUTDOWN
N
AuxFeedbackFault
(Aux Fdbk AQB)
E61
Auxiliary encoder has encountered an illegal state transition.
DISABLE
N
AuxFeedbackFault
(Aux Fdbk Loss)
E62
The feedback wiring is open, shorted, or missing.
DISABLE
N
AuxFeedbackNoise
(Aux Fdbk Noise)
E63
Presence of noise on auxiliary feedback cable.
DISABLE
Y
MotorFeedbackNoise
(Mtr Fdbk Noise)
E64
Presence of noise on motor feedback cable.
No Fault Message
(condition indicated by
on-screen message)
(Hookup Fault)
E65
Hookup procedure failed.
DISABLE
N
No Fault Message
(condition indicated by
on-screen message)
(Atune Flt)
E66
Autotune procedure failed.
DISABLE
N
Fault Message RSLogix
(HIM)
Error
Code
Description
Drive Fault
Action
RSLogix
Programmable
Fault Action?