Interfaces
A selectable output is available for monitoring by the user: ANALOG
1 (J1-31).
The following signals can be mapped to the analog output.
The following signals can also be monitored when ULTRA Master is
configured for Advanced Mode.
!
Intro
ATTENTION: The user must provide an external circuit
to ignore the analog output signal for two seconds after
power-up. After reset the analog output may be in an inde-
terminate state for a short period before it stabilizes at the
software controlled setting. Failure to observe this precau-
tion could result in severe bodily injury.
Table 6.15:
Analog Outputs: ANALOG 1
Analog
Output
Pin Number
Description
ANALOG 1
J1-31
Selectable analog output. Displays the selected firm-
ware variable along with selectable scale and offset.
The scale or offset are calculated as shown below.
ACOM
J1-28
Analog Common (return).
Table 6.16:
Analog Output Specifications
Parameter
Description
Minimum
Maximum
Output Current
Allowable current draw of the load
-2 mA
+2 mA
Output Signal
Range
Voltage range of the signal
-10 Volts
+10 Volts
Current – Command
Velocity – Command
Current – Average
Velocity – Error
Current – Peak +
Position – Motor Feedback
Current – Peak -
Position – Command
Current – Input Limit +
Position – Error
Current – Input Limit -
Position – Error Peak +
Velocity – Motor Feedback
Position – Error Peak -
Position – Master
Torque Current
Position – Loop Output
Field Current
Velocity – Loop Output
Torque Voltage Command