Cable diagrams, schematics and examples, Appendix b, Cable – Rockwell Automation 1398-DDM-xxx ULTRA 100 Series Drives Installation Manual User Manual
Page 203
Publication 1398-5.2 – PDF 1997
Appendix B
Cable Diagrams, Schematics and
Examples
Appendix B
Factory supplied cables allow ULTRA 100 Series drives to conform to
the European Union Directives when connecting the drive to motors,
controllers or computers. The following diagrams provide information
on the cables available from the factory.
Refer to Appendix A, “Options and Accessories” for ordering
information.
The information below applies to all factory supplied cables.
●
Wire Insulation Type: Polyvinyl Chloride
●
Conductor size: 0.08 mm
2
(28 AWG) tinned copper, except as
noted below.
[0.25 mm
2
(24 AWG) on 9101-1372, 9101-1374 and 9101-1379]
[1.5 mm
2
(16 AWG) on 9101-1190, 9101-1381, 9101-1385 and
9101-1467]
[2.5 mm
2
(14 AWG) on 9101-1191 and 9101-1382]
[6 mm
2
(10 AWG) on 9101-1192 and 9101-1383]
[10 mm
2
(8 AWG) on 9101-1384 and 9101-1399]
[16 mm
2
(6 AWG) on 9101-1193]
●
Braid Shield Coverage: 85% minimum
●
Jacket Material: Thermoplastic elastomer
●
Moldings: 105°C (221°F) Black PVC
●
Minimum Bend Radius
Control Cables
Motor Power Cables
Connector
mm (in.)
Cable
mm (in.)
Controller (J1)
171.45 (6.75)
9101-1190
91.70 (3.6)
Encoder (J2)
129.54 (5.10)
9101-1191
98.80 (3.9)
9101-1192
156.00 (6.1)
9101-1193
226.80 ( 8.9)
9101-1381
91.70 (3.6)
9101-1382
98.80 (3.9)
9101-1383
156.00 (6.1)
9101-1384
226.80 ( 8.9)
9101-1385
106.70 (4.2)
9101-1399
189.25 (7.5)
9101-1467
91.70 (3.6)