Application and Configuration Examples
5. Verify the communications port settings of the PC match those of
the drive.
• If the settings are correct, select
OK
in the Port - Settings dia-
log box.
• If the settings are different, correct the Port - Settings to allow
communications with the drive.
Factory default communications Port - Settings for the drive
are:
– Baud Rate:
9600
– Data Bits:
8
– Parity:
None
– Stop Bits:
1
– Serial Port:
COM1
Refer to the section “RS-232 Communication Test” on page 11-8
for troubleshooting instructions.
6. Select
Read Drive
P
arameters
from the Communications menu.
7. Verify the Drive Name and Address are correct for the drive that is
being addressed.
8. Choose
OK
to load the drive parameters.
Figure 8.7
Incremental Indexing Connection Diagram
J1
26 I/O PWR
20 ENABLE
21 FAULT
32 INPUT1
Close to ENABLE Drive
Close to RESET Fault
J4
DRIVE
TB1
2 RCV
3 XMT
5 COM
L1 3
L2/N 4
Gnd 5
XMT
RCV
COM
100-240 VAC
50/60 Hz
Single Phase
Power Source
TB1
Phase R 6
Phase S 7
Phase T 8
Motor Gnd 9
J2
Motor
Encoder
RESET
Close to Start INDEX
External I/O
12-24 VDC
Power Source
5 I/O PWR
6 I/O COM
Note: A motor must be selected for the parameters to load.