Publication 1398-5.2 – PDF 1997
G-2
Specifications
Digital Outputs
Selectable (2)
12-24 Volt, Short Circuit Protected, Optically Isolated, Sin-
gle-ended, Active High, 50 mA maximum
BRAKE
Normally Open Relay, 1 A
READY
Normally Open Relay, 100 mA
Digital I/O Power Supply
User supplied 12 to 24 VDC
Analog Inputs
Current Limit
(I LIMIT)
0 to 10 Volt, single-ended, 5 kOhm input Impedance
COMMAND
±10 Volt, Differential, 13 kOhm input Impedance, offset soft-
ware adjustable
Analog Outputs
ANALOG1
0 to 10 Volt, 8 bits, 2 mA maximum
Auxiliary Encoder Input
Auxiliary Encoder Signal Input
26LS33 Input, 4 MHz Count Frequency
Differential/Single-ended
A/B
Step/Direction
CW/CCW
Motor Encoder Output
Motor Encoder Output
AM26C31 or AM26LS31 Differential Driver, Divide by 1, 2, 4,
or 8
Differential output is 2.0 Vdc across a 100 Ohm load
Memory
Parameter Data Retention
20 years
Motor Protection
Motor Overload Protection
The drive utilizes solid state motor overload protection which
operates:
• within 8 minutes at 200% overload
• within 20 seconds at 600% overload
Speed Regulation
Type
Digital, PI
-3dB Bandwidth
300 Hz
-45° Bandwidth
50 Hz
Ripple
±0.44 rpm with 5000 line encoder
Speed Range
1:8000 rpm
Position Regulation
Type
Digital, PI with Feedforward
Filters
Low Pass
Digital, 0 - 1000 Hz, -3 dB Bandwidth, Selectable