Application and Configuration Examples
8-33
9. If the message box appears that a motor must be selected, select
OK. The Drive Setup window is displayed with Motor Model
selection parameter active. The motor may be selected from the
drop down box. If this message box does not appear, the motor
displayed in the Motor Model box was previously selected.
10. Select or verify the correct motor model number from the drop
down Motor Model list.
11. If a message advises that the drive must be reset, choose
Yes
.
12. Select
Inde
x
ing
as the Operation Mode for the drive.
13. Choose
Close
to exit the Drive Set Up window.
14. Choose the
Drive
P
arameters
command icon from the Drive
window and then select the
Indexing tab
.
15. Enter the following values for Index 0. Refer to “Incremental
Indexing Examples” on page 8-30 for examples of Single and
Batched Incremental Indexing profiles.
16. Choose
Close
to exit the Drive Parameters window.
17. Verify the Status indicator is green.
18. Select the
I/O
C
onfiguration
command icon from the Drive Win-
dow.
19. Select an appropriate digital input from the pull-down lists avail-
able as Digital Input Assignments in the I/O Configuration win-
dow.
For example:
•
Start Index
as Input 1
•
Not Assigned
as Inputs 2 through 3.
Single Move Settings
Batched Move Settings
Incremental
as Mode
Incremental
as Mode
8000
as Distance
8000
as Distance
1
as the Batch Count
3
as the Batch Count
0
as Dwell
1000
as Dwell
Appropriate values for
Acceleration and Decelera-
tion
Appropriate values for
Acceleration and Decelera-
tion