Creating Custom Motor Files

D-17

The back-EMF constant of the motor, before gearing, is computed as:

Note that the back-EMF was specified as a per phase value, and is
doubled to obtain a line-to-line value.

The motor inertia, before gearing, is computed as:

The resistance and inductances are also specified as per phase values,
and are computed as:

The thermal constant is specified in minutes, and is computed as:

Custom Motor File

The custom motor file parameters are as follows:

Intro

Intro

( )

V

rev

min

50

4000

rev

min

MAX

= 





=

80

K

270

in lb

Amp

1

8.85075

N m

in lb

1

50

0.61

N m

Amp

T

=



 ⋅





⋅ 





=

Intro

( )

K

1.1

Volts

RPM

1000

1

RPM

KRPM

2

1

50

44

Volts

KRPM

E

= 





⋅ 





⋅ 





=

Intro

(

)

J

5 in lb s

1129.85

Kg cm

in lb s

1

50

2.26 Kg cm

M

2

2

2

2

2

=

⋅ ⋅

⋅ ⋅



 ⋅ 



=

Intro

( )

L

5.0

mH

Phase

2

10.0 mH

L -L

= 





=

( )

R

3.7

Ohms

Phase

2

7.4 Ohms

L -L

= 





=

Intro

(

)

thermal time constant

30 min

60

sec

min

1800 sec

=

⋅ 





=

GENERAL

CURRENT LOOP

Motor Model:

A_CUSTOM

Current Feedforward:

0 degrees / kRPM

Table ID:

-1

Motor File:

CUSTOM21.MTR

ELECTRICAL

Motor Type:

Synchronous

Resistance:

7.4 Ohms

Number of Poles:

8

Inductance:

10.0 mH

Kt:

0.61 N-m/Amp