Avaya Cajun P882 User Manual
Page 475

Cajun P550/P880/P882 Switch User Guide
Monitoring the Cajun Switch
17-15
4. Refer to Table 17-7 for an explanation of the items listed in
the Class column on the General Event Management dialog
box:
5. Click APPLY to save your changes, or CANCEL to restore
previous settings.
Table 17-7. Class Column Items
Class
Determines whether or not the switch
sends a notification...
Start
Upon system start.
System
For system events.
Configuration
For each configuration change (for example,
enabling and disabling ports).
Temperature Status
Of temperature status changes. Temperature
status message could precede a switch
shutdown, and are often critical.
Resource
Upon a change in system resources.
Fan Status
Of fan status. Fan failures will eventually lead to
overheating the system. Fan Status message
provide a good early warning for a failure that
could eventually cause the switch to shut down.
Service Port Status/
User Port Status
Of Port status changes for service and user ports.
Set a port as either service port/user port from
the port configuration page. The purpose of this
feature is to allow you to use different
notification level for critical (service ports), if
desired.
Authentication
Failure
When the switch detects an authentication
failure. This is a security-related feature used to
detect unauthorized SNMP activity.
Bridge Status
Of changes in bridge status.
Switch Fabric
Of failures in the switch fabric. These are critical
failures and should be monitored closely.
OSPF
For OSPF events if OSPF protocol event logging
is enabled.
RIP
For RIP events if RIP protocol event logging is
enabled.
LDAP
For LDAP events if LDAP protocol event logging
is enabled.
AppleTalk
For AppleTalk events if AppleTalk protocol event
logging is enabled.