Allied Telesis AT-WA7501 User Manual
Page 285

AT-WA7500 and AT-WA7501 Installation and User’s Guide
285
For details about using segment numbers and names for an access point,
which contains only one flash memory segment, see “Understanding the
Access Point Segments” on page 270.
FB
Purpose:
Makes an inactive segment the active segment. Because the AT-WA7500
and AT-WA7501 have only one flash memory segment, this command has
no affect on the access points. This command is included here for
backward compatibility with older scripts only.
Syntax:
FB
bootsegment
datasegment
where:
bootsegment
is the name or number of the boot segment to be
activated.
datasegment
is the name or number of the data segment to be
activated.
Example:
These examples apply to non-AT-WA7500 and AT-WA7501 products and
are included for your reference only.
To make segment 2 the active boot segment and segment 4 the active
data segment, enter:
FB 2 4
You can use an asterisk instead of a segment name if you want to leave
that segment unchanged. For example, to leave the active boot segment
unchanged and make segment 4 the active data segment, you could
enter:
FB * 4
After loading software into the access point a common task is to activate
the new software. To activate the new software, enter:
FB IB: ID:
This command activates the inactive boot and data segments. You do not
need to know which of the boot and data segment numbers the flash is
loaded into.