Allied Telesis AT-WA7501 User Manual
Page 279

AT-WA7500 and AT-WA7501 Installation and User’s Guide
279
where:
bootsegment
is the name or number of the boot segment to be
activated.
datasegment
is the optional name or number of the data segment to
be activated.
Example:
These examples apply to non-AT-WA7500 and AT-WA7501products and
are included for your reference only.
To make segment 2 the active boot segment and segment 4 the active
data segment, enter:
FB 2 4
You can use an asterisk instead of a segment name if you want to leave
that segment unchanged. For example, to leave the active boot segment
unchanged and make segment 4 the active data segment, you could
enter:
FB * 4
After loading software into the access point a common task is to activate
the new software. To activate the new software, enter:
FB IB: ID:
This command activates the inactive boot and data segments. You do not
need to know which of the boot and data segment numbers the flash is
loaded into.
FC
Purpose:
Compacts the files in a particular segment.
Syntax:
FC
s
where s indicates the segment to be compacted. You can use any
segment number or name to specify the one flash memory segment on the
access point.