beautypg.com

Show poe config – Allied Telesis AT-S62 User Manual

Page 356

background image

Chapter 22: Power Over Ethernet Commands

356

SHOW POE CONFIG

Syntax

show poe config [port=port]

Parameter

port

Specifies a port. You can specify more than one port at

a time. You can specify the ports individually (e.g.,
5,7,22), as a range (e.g., 18-23), or both (e.g., 1,5,14-22).

Description

Entering this command without specifying a port displays the following
PoE information:

❑ Maximum available power - The total available power for PoE

supplied by the switch. This value is 400 W for the AT-8524POE
switch.

❑ Power threshold - A percentage of the maximum available power

which, if exceeded by the powered devices, causes the switch to
send an SNMP trap to your management workstation and enter
an event in the event log. At the default setting of 95%, the switch
sends an SNMP trap when the PoE devices require more than 380
W, which is 95% of 400 W, the maximum available power on the
AT-8524POE switch.

Entering the command with the PORT parameter, displays this PoE
information about the specified port:

❑ PoE function - The status of PoE on a port, which can be either

enabled or disabled. The default is enabled.

❑ Power priority - The port’s priority, which can be critical, high, or

low. The default is low.

❑ Power limit - The maximum amount of power available to a

powered device. The default value is 15.4 W.

Examples

This command displays general PoE information:

show poe config

This command displays PoE information about port 4:

show poe config port=4