beautypg.com

Set snmpv3 targetaddr – Allied Telesis AT-S62 User Manual

Page 141

background image

AT-S62 Command Line User’s Guide

141

SET SNMPV3 TARGETADDR

Syntax

set snmpv3 targetaddr=targetaddr params=params
ipaddress=ipaddress udpport=udpport
timeout=timeout retries=retries taglist=taglist
[storagetype=volatile|nonvolatile]

Parameters

targetaddr

Specifies the name of the SNMP entity (NMS or

manager) that manages the SNMP activity on the
switch, up to 32 alphanumeric characters.

params

Specifies the target parameters name, up to 32

alphanumeric characters. This is an optional
parameter.

ipaddress

Specifies the IP address of the host. This is an optional

parameter.

udpport

Specifies the UDP port in the range of 0 to 65535. The

default UDP port is 162. This is an optional parameter.

timeout

Specifies the timeout value in milliseconds. The range

is 0 to 2,147,483,647 milliseconds, and the default is
1500 milliseconds. This is an optional parameter.

retries

Specifies the number of times the switch retries to

send an inform message. The default is 3. This is an
optional parameter.

taglist

Specifies a tag or list of tags, up to 256 alphanumeric

characters. Use a space to separate entries. This is an
optional parameter.

storagetype

Specifies the storage type of this table entry. This is an

optional parameter. The options are:

volatile

Does not allow you to save the table

entry to the configuration file on the
switch. This is the default.

nonvolatile

Allows you to save the table entry to

the configuration file on the switch.