background image

AT-S101 Management Software User’s Guide

81

4. Click the dialog boxes of the ports that will make up the port trunk.

A check in a box indicates the port is a member of the trunk. No check
means the port is not a member. A port trunk can contain up to eight
ports.

5. Change the status of the trunk from Disable to one of the following:

Active
The aggregator will broadcast and respond to LACPDU (LACP Data
Unit) packets.

Passive
The aggregator will not broadcast LACPDU packets, but it will respond
to them.

Manual
Enables static port trunking and disables LACP.

6. Click Apply.

The trunk is now operational on the switch.

7. Configure the port trunk on the other switch and connect the cables.

8. From the menu on the left side of the page, select Save Configuration

to Flash to save your changes.