Chapter 21: Statistics

228

3. To view historical statistics, click on the arrow next to “Statistics” and

select one of the options in Table 7.

4. To select the amount of time before the screen is refreshed, click Auto

Refresh. Choose from the following options:

5 seconds

10 seconds

Table 7 Historical Status Options

Option

Definition

Inbound Octet Rate (Bytes)

Measures the rate of inbound octet bits in bytes
per second.

Inbound Unicast Packet Rate (Pkts)

Measures the rate of inbound unicast packets in
packets per second.

Inbound Non-unicast Packet Rate (Pkts)

Measures the rate of inbound non-unicast packets
(such as broadcast and multicast packets) in
packets per second.

Inbound Discards (Pkts)

Measures the number of inbound discarded
packets in packets per second.

Inbound Errors (Pkts)

Measures the number of inbound errors in
packets per second.

Outbound Octets (Bytes)

Measures the number of outbound octet bits in
bytes per second.

Outbound Unicast Packets (Pkts)

Measures the number of outbound unicast
packets in packets per second.

Outbound Non-unicast Packets (Pkts)

Measures the number of outbound non-unicast
(such as broadcast and multicast packets)
packets.

Outbound Discards (Pkts)

Measures the number of outbound discarded
packets.

Outbound Errors (Pkts)

Measures the number of outbound error packets.

Ethernet Undersize Packets (Pkts)

Measures the number of undersized Ethernet
packets.

Ethernet Oversize Packet Rate (Pkts)

Measures the number of oversized Ethernet
packets.