Overview, Radius implementation guidelines – Allied Telesis AT-S101 User Manual
Page 170

Chapter 15: RADIUS Authentication Protocol
170
Overview
RADIUS (Remote Authentication Dial In User Services) is an 
authentication protocol for enhancing the security of your network. The 
protocol transfers the task of authenticating network access from a 
network device to an authentication protocol server.
The AT-S101 Management Software comes with RADIUS client software. 
You can use the client software together with 802.1x port-based network 
access control. See Chapter 17, “802.1x Port-based Network Access 
Control” on page 191, to control which end users and end nodes can send 
packets through the switch.
RADIUS
Implementation
Guidelines
What do you need to use the RADIUS protocol? Following are the main 
points.
You must install RADIUS server software on a network server or 
management station. Authentication protocol server software is not 
available from Allied Telesis.
The RADIUS server must communicate with the switch through a port 
that is an untagged member of the Default VLAN.
If the RADIUS server is on a different subnet from switch, be sure to 
specify a default gateway in the IP Setup Page, so that the switch and 
server can communicate with each other. See “Configuring an IP 
Address, Subnet Mask and Gateway Address” on page 22.
You need to configure the RADIUS server software on the 
authentication server by specifying the username and password 
combinations. The maximum length of a username or password is 12 
alphanumeric characters.
Note
This manual does not explain how to configure RADIUS server 
software. Refer to the documentation that came with the software for 
instructions.
You must activate the RADIUS client software on the switch using the 
AT-S101 Management Software and configure the settings. This is 
explained in “Configuring the RADIUS Client” on page 171. By default, 
authentication protocol is disabled.
Note
For more information on the RADIUS authentication protocol, refer 
to the RFC 2865 standard.