HP Brocade 4Gb SAN Switch for HP BladeSystem c-Class User Manual
Page 133

Fabric OS 5.0.0 Advanced Web Tools user guide 133
1.
Launch the Fabric Watch module as described in ”
To launch the Fabric Watch module:
2.
Click the Threshold Configuration tab.
3.
Click the Alarm Configuration subtab.
4.
Click a class from the Fabric Watch navigation tree.
5.
Select an area from the Area Selection menu in the Threshold Configuration tab.
The module displays two tables of alarm configuration information, labeled System Default and Custom
Defined. You cannot modify the information in the System Default table.
6.
Select the System Default radio button in the Activate Level section to use the system default settings,
or select the Custom Defined radio button in the Activate Level section to specify
new settings and proceed to the next step.
7.
Select a check box to set the type of notification method for each event type (Changed, Below, Above,
Inbetween). The available alarm actions are ERROR_LOG, SNMP_TRAP, RAPI_TRAP, and
EMAIL_ALERT.
8.
Click Apply.
Enabling and disabling threshold alarms for individual elements
Use the Element Configuration subtab to configure element-specific alarm settings. To enable or disable
threshold alarms for an element:
1.
Launch the Fabric Watch module as described in ”
To launch the Fabric Watch module:
2.
Click a class from the Fabric Watch navigation tree.
You can set alarms for information on a switch only if that information is monitored by Fabric Watch for
that switch; not all alarm options are available for all switches. For more information, refer to the HP
StorageWorks Fabric Watch 4.4.x user guide.
3.
Click the Threshold Configuration tab.
4.
Select the area with the alarms that you want to enable or disable from the Area Selection menu.
5.
Click the Element Configuration subtab.
6.
Select an element from the Element Selection menu.
7.
To disable threshold alarms, select Disabled in the Status area and then click Apply. The threshold
alarms are disabled and you do not need to continue with this procedure.
To enable threshold alarms, select Enabled in the Status area and continue with the next step.
8.
Select a behavior type for the threshold alarms:
• Select Triggered to receive threshold alarms only when they are triggered by events that you have
defined.
• Select Continuous to receive threshold alarms at a continuous interval. Select a time interval in
which to receive the threshold alarms from the Time Interval menu.
9.
Click Apply.
10.
Optional: Apply the selections on this panel to multiple elements simultaneously.
a. Click Apply More.
The Multiple Selection dialog box opens
b. Click the boxes next to the indices of all applicable elements.
c. Click OK.