General advanced web tools issues and workarounds, Table 11 advanced web tools issues and workarounds, 11 advanced web tools issues and workarounds – HP Brocade 4Gb SAN Switch for HP BladeSystem c-Class User Manual
Page 140: Table 11, Figure 11

140 Issues and workarounds
General Advanced Web Tools issues and
workarounds
lists issues and workarounds that apply to all browsers and switch platforms.
Table 11
Advanced Web Tools issues and workarounds
Issue
Details
Browser
The Fabric Watch, Switch Admin, HA, Name Server, and Zone Admin
modules are separate applets embedded in HTML pages. The successful
launch of the applet depends on whether the browser can successfully
load the HTML page. Occasionally, you may see a blank browser
window with the message l
oading pages...
that is stuck. This is
likely caused by a sudden loss of switch web server (either by normal
HA failover, reboot, or other causes).
Workaround: If the Fabric Watch, Switch Admin, HA, Name Server, or
Zone Admin modules hang, close this window and relaunch the module.
Browser
An Advanced Web Tools browser window may stop responding
following an HA failover immediately after a zoning configuration is
enabled or disabled. It is likely that the web daemon was terminated by
the HA failover before the HTTP request was sent back.
Workaround: If one of the Advanced Web Tools modules is hanging,
close the window and relaunch the module. If the module is locked, shut
down and relaunch the Advanced Web Tools application.