beautypg.com

Disabling a zone configuration, Displaying the enabled zone configuration, Figure 34 effective configuration window – HP Brocade 4Gb SAN Switch for HP BladeSystem c-Class User Manual

Page 107: 34 effective configuration window

background image

Fabric OS 5.0.0 Advanced Web Tools user guide 107

Disabling a zone configuration

When you disable the active configuration, the Advanced Zoning feature is disabled on the fabric and all

devices within the fabric can communicate with all other devices. This does not mean that the zoning

database is deleted, however, only that there is no configuration active on the fabric.

When you disable a zone configuration from Advanced Web Tools, keep in mind that the entire zoning

database is automatically saved, and then the selected zone configuration is disabled.

To disable a zone configuration:

1.

Launch the Zone Admin module as described on

page 95

.

2.

Select Actions > Disable Zoning.
The Disable Config warning is displayed.

3.

Click Yes to save and disable the current configuration.

Displaying the enabled zone configuration

The enabled zone configuration screen displays the actual content of the single zone configuration that is

currently enabled on the fabric, whether or not it matches the configuration that was enabled when the

current Zone Admin session was launched or last refreshed (see

Figure 34

). The zones, QuickLoops, and

FA zones are displayed, and their contents (ports, WWNs, AL_PAs) are displayed next to them. Aliases

are not displayed in the enabled zone configuration. If there is no active zone configuration enabled on

the switch, a message is displayed to that effect.

The enabled configuration is listed in the top right corner of the Zone Admin module.

Figure 34

Effective Configuration window

To view the enabled zone configuration name without launching the Zone Admin module:

Select a switch from the Fabric Tree.

The selected switch appears in the Switch View. The current zone configuration name (if one is

enabled) is displayed in the lower portion of the Switch Information View. If no zone configuration is

enabled, the field displays

none

.

To view detailed information about the enabled zone configuration: