Configuring fan frame notification parameters – HP Brocade 4Gb SAN Switch for HP BladeSystem c-Class User Manual

Page 51

background image

Fabric OS 5.0.0 Advanced Web Tools user guide

51

To enable insistent domain ID mode:

1.

Launch the Switch Admin module as described on

page 43

.

2.

Disable the switch (see

Enabling and disabling a switch

” on page 46).

3.

Click the Configure tab.

4.

Click the Fabric subtab.

5.

Select the Insistent Domain ID Mode check box.

6.

Click Apply.

7.

Enable the switch (see

Enabling and disabling a switch

” on page 46).

Configuring FAN frame notification parameters

You can specify whether fabric access notification (FAN) frames are sent to public loop devices to notify

them of their node ID and address.

When you configure FAN frame notification parameters for the Core Switch 2/64 or SAN Director 2/128

configured with two logical switches, the configuration is on a logical-switch basis. This means that for

each logical switch, you must configure FAN frame notification parameters individually.

To configure FAN frame notification parameters:

1.

Launch the Switch Admin module as described on

page 43

.

2.

Disable the switch (see

Enabling and disabling a switch

” on page 46).

3.

Click the Configure tab.

4.

Click the Arbitrated Loop subtab.

5.

Select the Send FAN Frames check box.

6.

Click Apply.

7.

Enable the switch (see

Enabling and disabling a switch

” on page 46).