Figure 11 extended fabric tab, 11 extended fabric tab, Place – HP Brocade 4Gb SAN Switch for HP BladeSystem c-Class User Manual
Page 56: Figure 11, N in
![background image](/manuals/397880/56/background.png)
56
Managing your fabrics, switches, and ports
Figure 11
Extended Fabric tab
To configure a port for long-distance connection:
1.
Launch the Switch Admin module as described on
2.
Click the Extended Fabric tab.
3.
Perform of the following, depending on the type of switch:
• For Core Switch 2/64 and SAN Director 2/128, select the slot subtab that corresponds to the
correct slot for the logical switch.
• For HP StorageWorks SAN Switch 2/8V, SAN Switch 2/16V, SAN Switch 2/32, and SAN Switch
4/32, proceed directly to the next step.
4.
Select a port by clicking anywhere in the row for that port.
5.
Select a distance from the Long Distance list that corresponds to the port.
Depending on the distance selected, a license may be required. For information about the various
If you select a long-distance setting of
LD
, you must also enter a value in the Desired Distance column
for that port number:
a. Double-click the Desired Distance field for the port, as shown in
b. Enter a number in the field to indicate the distance in kilometers:
For 1 Gbps ports, enter a number between 10 and 500, inclusive.
For 2 Gbps ports, enter a number between 10 and 250, inclusive.
For 4 Gbps ports, enter a number between 10 and 125, inclusive.