Rebooting the switch, Performing a fast boot, Performing a reboot – HP Brocade 4Gb SAN Switch for HP BladeSystem c-Class User Manual
Page 48: Configuring fabric parameters

48
Managing your fabrics, switches, and ports
To view or print a switch report:
1.
Launch the Switch Admin module as described on
2.
Click the Switch tab.
3.
Click View Report.
A switch report opens in a new window.
4.
View or print the report using your browser.
Rebooting the switch
When you reboot the switch, the reboot takes effect immediately.
Performing a fast boot
A fast boot reduces boot time significantly by bypassing power-on self test (POST). To perform a switch fast
boot:
1.
Launch the Switch Admin module as described on
2.
Click the Firmware tab (see
3.
Select the Fastboot radio button.
4.
Click Apply.
Performing a reboot
Use the following procedure to reboot the CP and execute the normal power-on booting sequence:
1.
Launch the Switch Admin module as described on
2.
Click the Firmware tab (see
3.
Select the Reboot radio button.
4.
Click Apply.
Configuring fabric parameters
When you configure fabric parameters for the Core Switch 2/64 or SAN Director 2/128 configured with
two logical switches, the configuration is on a logical-switch basis. This means that for each logical switch,
you must configure fabric parameters individually.
NOTE:
You must disable the switch before you can configure fabric parameters.
You can configure the following fabric parameters with the Configure tab and Fabric subtab of the Switch
Admin module (as shown in
•
BB Credit: Configures the number of buffers that are available to attached devices for frame receipt.
The default BB Credit is 16. The range is 1 through 27.
•
R_A_TOV: Resource allocation time-out value (in milliseconds). This variable works with the E_D_TOV
to determine switch actions when presented with an error condition. The default is 10000. The
possible range is 4000 through 120000.