Ups (6770 switch module), Attributes, Physical – HP NonStop G-Series User Manual

Page 264: Logical, Actions, Replace, Ups physical logical, Uninterruptible power supply (ups)

background image

UPS (6770 Switch Module)

The uninterruptible power supply (UPS) is a component of a

6770 switch module

that provides two hours of power if

both the primary and backup AC power sources fail.

Location in OSM tree:External ServerNet Fabric > Switch Group > Switch Module > UPS

Example:UPS $ZZSMN.X1

Attributes

UPS

Displayed in the Attributes tab and Attributes dialog box only if the value is something
other than OK.

Values

Service State

Physical

The part number of the UPS.

Part Number

A unique serial number that identifies the component. Track IDs are used for tracking
components.

Track ID

The VA rating (volts multiplied by amps) and the firmware version of the UPS.
Example: UPS 1440 VA FW -0039

Type

Logical

The percentage of charge remaining in the UPS batteries.

Estimated Charge Remaining

The amount of time remaining (in minutes) that the UPS battery will provide power
to the switch in the event that both the primary and backup rails lose power, or if the
input voltage of the AC power source is not within the allowable range.

Remaining Time

The remaining capacity level in the UPS batteries.
Values: Normal, Low, Depleted

If the value is Depleted, the UPS is unable to sustain the present load if utility power
is lost or absent.

Remaining Capacity Status

Actions

Replace

Launches the Replace Switch Component guided procedure, which provides help for replacing the component.