Power supply (vio), Attributes, Vio power supply – HP NonStop G-Series User Manual
Page 178: Physical, Logical, Configuration, Actions, Configure power source as ac, Configure power source as ups, Delete the power source configuration

Power Supply (VIO)
Provides power to the VIO enclosure (represented in the OSM Service Connection as
). There are two
VIO power supplies in each VIO enclosure.
Attributes
VIO Power Supply
Displayed in the Attributes tab and Attributes dialog box only if the value is something
other than OK.
Service State
Physical
Identifies the manufacturer of the component.
Displayed for VIO power supplies in S-series VIO modules only.
Manufacturer
The part number of the component that was assigned in manufacturing. Use part
numbers for identifying and ordering parts.
Part Number
Logical
The state of the component as known to the operating system on the server.
Device State
Configuration
NOTE:
These attributes are not displayed for a power supply unit in an S-series VIO Module.
Indicates the state of this power supply's backup power configuration as known to
OSM.
Values: Not Configured, AC, UPS, Unknown
You must use the
action to set this value to UPS
in order for OSM to provide an orderly system shutdown in the event that a power
failure exceeds the powerfail-delay time interval specified for your rack-integrated
UPS.
Power Source
The IP address of the UPS configured to provide backup power in the event of a
power failure, if specified through the
UPS IP Address
Actions
Configure Power Source as AC
Sets the Configuration > Power Supply attribute value for this power supply to AC.You must be logged on as super.super
to perform this action.
NOTE:
This action is not valid for a power supply unit in an S-series VIO Module.
Configure Power Source as UPS
Sets the Power Source attribute value for this power supply to UPS. You must be logged on as super.super to perform
this action. Upon initiating the action, you are prompted to enter the IP address of the UPS.
You must use this action to configure at least one of your VIO power supplies (to specify UPS as the backup power
source) in order for OSM to provide an orderly system shutdown in the event that a power failure exceeds the
powerfail-delay time interval specified for your UPS. For more information on preparing for AC power-fail scenarios,
see the NonStop NS14000 Series, NS1200, or NS1000 Planning Guide. For more information on using the
POWERFAIL_DELAY_TIME command to specify the Power-Failure-to-Shutdown time interval, see the SCF Reference
Manual for the Kernel Subsystem.
NOTE:
This action is not valid for a power supply unit in an S-series VIO Module.
Delete the Power Source Configuration
Sets the Configuration > Power Supply attribute value to Not Configured. You must be logged on as super.super to
perform this action.
178
System Resources