Switch-to-Node PIC

A plug-in card (PIC) on the

6770 switch module

that connects to a ServerNet node. The last part of the name contains

the port number where the PIC is located. Only the PICs in ports 0 through 7 of the switch are used for switch-to-node
connections.

Location in OSM tree: External ServerNet Fabric > Switch Group > Switch Module > Switch > Switch PIC

Example: Switch PIC $ZZSMN.X2.4 (indicates the PIC in port 4 of switch X2)

Attributes

Switch PIC

Displayed in the Attributes tab and Attributes dialog box only if the value is something
other than OK.

Values

Service State

Logical

The state of connectivity between the switch and the node to which this PIC connects.
Values:

Connected
Not Connected
Connected to Switch With Wrong Fabric
Connected to Node
Connected to Wrong Port
Connected to Different Switch
Connected to Switch With Wrong Configuration
Unknown

Connectivity Status

Whether the PIC is installed and responding.
Values: Present, Absent, Unknown

Presence

The state of the external ServerNet fabric from the local node to the remote node
connected via this port.

Values

Fabric State

Neighbor ServerNet Node

The neighbor node to which this PIC is connected.
Example: ServerNet Local Node \STAR1

Node Name

The ServerNet node number of the neighbor node to which this PIC is connected.

Node Number

Actions

Node Responsive Test

Tests the connectivity on the external ServerNet fabric through this port.

258