Servernet port, Attributes, Logical – HP NonStop G-Series User Manual
Page 186: Actions
ServerNet Port
In OSM, this object represents ports on:
•
ServerNet PICs located within Processor Switches
•
ServerNet Switch Boards located within IOAM Enclosures
•
4-Port ServerNet Extenders (4PSEs) located only in HP Integrity NonStop NonStop NS14000 or NonStop NS1000
systems containing IOAMs
•
located in systems containing VIO enclosures.
OSM displays five ports under a VIO Logic Board -- ports 1 through 4 provide connectivity to processors 0 through
3; port 5 represents the crosslink connectivity to the VIO enclosure on the opposite fabric.
•
located only in HP Integrity NonStop NonStop NS14000 series, NS1200, or NonStop
NS1000 systems containing VIO enclosures.
In slot 2, an extender PIC can be used for connectivity to additional processors, with ports 1 through 4
corresponding to processors 4 through 7.
In slot 5 (Integrity NonStop NS14000 series servers only), an extender PIC can be used for ServerNet cluster
connectivity. Port 1 is where the cable from the cluster switch is physically connected to. For more information
about ServerNet cluster connectivity for VIO enclosures, see the ServerNet Cluster Supplement for NS-Series.
•
ServerNet switches located in Enclosures in NonStop BladeSystems. Under these port objects, OSM displays
Fiber objects.
Attributes
Logical
Displays the status of this port.
Values: Disabled, Neighbor Check In Progress, Enabled
Link Status
Displays the status of the port to which this port is connected.
Values: OK, Fabric connection error, PIC connection error, Port connection error,
Domain connection error, System connection error, Timeout error, Unknown
Neighbor Check Status
NOTE:
In processor switches, these attributes are not displayed for Port 1 of the crosslink PIC located in slot 3.
Actions
None.
186