Firmware

The VPROC of the firmware currently loaded on the FRU.

Version

The name of the file to be used for a firmware update.

Default File Name

The version of the firmware to be used for a firmware update .

Default File Version

The differences, if any, between the current and default firmware versions.

Values

Compare State

Actions

Add LBU

Configures a ServerNet/FX or ServerNet/FX2 adapter as an LBU. An LBU is the SCF logical equivalent for the adapter.

Delete LBU

Removes an LBU from the system configuration database. An LBU is the SCF logical equivalent for the ServerNet/FX
or ServerNet/FX2 adapter.

Dump Controller

Writes the data from the memory of the ServerNet/FX or ServerNet/FX 2 adapter field-replaceable unit (FRU) to the
file $SYSTEM.ZSERVICE.ZFOXDUMP.

The ServerNet/FX FRU must be in the Stopped state to perform this action.

External Loopback Test

Performs the external loopback firmware diagnostic test.

Before running this test, you must use the Stop action to put the ServerNet/FX or ServerNet/FX 2 adapter
field-replaceable unit (FRU) in the Stopped state.

Firmware Update

Updates the firmware for a ServerNet/FX adapter (FXSA) or ServerNet/FX 2 adapter (FX2SA).

Responsive Test

Verifies that the component is installed and responding.

Set FOX Cluster Number

Sets the node to which the ServerNet/FX or ServerNet/FX2 adapter FRU is connected.

Set Left Transmitter Power Level

Sets the fiber-optic transmitter LED power for the right direction on the FOX ring.

High LED power is suitable for distances of 2 km through 4 km.

Low LED power is suitable for distances of less than 2 km.

Before setting the LED power level, you must use the Stop action to put the ServerNet/FX or ServerNet/FX 2 adapter
FRU in the Stopped state. The current power level is indicated by the

Left Transmitter Power Level

attribute.

Set Right Transmitter Power Level

Sets the fiber-optic transmitter LED power for the right direction on the FOX ring.

High LED power is suitable for distances of 2 km through 4 km.

Low LED power is suitable for distances of less than 2 km.

Before setting the LED power level, you must use the Stop action to put the ServerNet/FX or ServerNet/FX 2 adapter
FRU in the Stopped state. The current power level is indicated by the

Right Transmitter Power Level

attribute.

Start

Starts the ServerNet/FX or ServerNet/FX 2 adapter field-replaceable unit (FRU) that is in the Stopped state. During
startup, the controller operational code is automatically loaded into the FRU. When the Start action completes, the
FRU is in the Started state.

FXSA / FX2SA (ServerNet/FX / ServerNet/FX2)