Blink LED On

Causes the LED to blink on and off.

SCF Equivalent: SCF ALTER SWITCH $ZZSMN, NEAREST { X | Y}, BLINK ALL

Configuration Update

This action updates the configuration for the ServerNet II switch component of the 6770 switch module. For more
information, see

Updating Cluster Switches

.

NOTE:

If you are updating both firmware and configuration on the same cluster switch, you should always update

the firmware first. In some circumstances, updating both firmware and configuration is not necessary. For more
information, see the ServerNet Cluster Manual.

Optional Parameter: File name of the configuration file.

Firmware Update

Updates the firmware on the ServerNet II switch component of the 6770 switch module. For more information, see

Updating Cluster Switches

.

Optional Parameter: File name of the firmware file.

Hard Reset

Is necessary following a Configuration Update action in order for the changes to take effect.

CAUTION:

This action disrupts the ServerNet traffic through this switch.

SCF Equivalent: SCF RESET SWITCH $ZZSMN, NEAREST { X | Y }, HARD

Prepare to Replace

Must be performed from each node of a ServerNet cluster before replacing a ServerNet II Switch for SANMAN to
accept the new switch.

Replace

Launches the guided procedure for replacing a ServerNet II Switch.

Set Fabric Setting

Sets the fabric LED indicator for the ServerNet II Switch to either X or Y.

Within three minutes after the action completes, the SANMAN process running on each of the nodes discovers that
the fabric setting has been corrected and accepts the new switch.

Parameter: Fabric Setting can be set to Unknown, Clear, X,or Y.

SCF Equivalent: SCF ALTER SWITCH $ZZSMN, NEAREST { X | Y }, FABRIC { X| Y }

Soft Reset

Used following a Firmware Update action on the switch for the changes to take effect.

SCF Equivalent: SCF RESET SWITCH $ZZSMN, NEAREST { X | Y }, SOFT